Home > Spring Energized Seals > Canted Coil Spring Seals > Static Radial Canted Coil Spring Energized Seal

Static Radial Canted Coil Spring Energized Seal (Code: HCC001)

Single-acting static sealing with controlled spring loading for stationary shaft-to-housing interfaces.

This seal combines a polymer jacket with a canted coil spring energizer for static radial sealing. Installed in a housing groove, it seals against the outside diameter of a stationary shaft.

The spring provides near-constant loading within its working deflection range, helping maintain sealing contact as mating dimensions change. Jacket material and spring alloy are selected to suit the operating media, temperature and pressure.

Features & Benefits

  • Consistent spring loading: Near-constant force across the working deflection range helps maintain sealing contact.

  • Dimensional compensation: Spring deflection accommodates changes in mating dimensions within the designed gland limits.

  • Application-specific materials: Jacket polymers and spring alloys are selected for the media and operating conditions.

Typical Applications

  • Stationary internally pressurized covers and flanges where the pressure, temperature or assembled gap calls for additional heel support

HCC001 static radial seal with a canted coil spring inside a polymer jacket

Technical Details

The shaft and housing remain stationary, with pressure acting from one side. Confirm the assembled radial extrusion gap, including dimensional tolerances and changes under pressure and temperature.

Motion & Pressure Action

Coloured icons show the primary duty, applications requiring review and the specified pressure action.
Grey icons mark duties outside the published configuration.

Reciprocating sealing — not specified for this seal

Reciprocating
Not specified

Rotary sealing — not specified for this seal

Rotary
Not specified

Combined rotary and axial motion — not specified for this seal

Helical Motion
Not specified

Oscillating motion — not specified for this seal

Oscillating
Not specified

Static radial sealing — primary application

Static
Primary application

Double-acting sealing — not specified for this seal

Double-Acting
Not specified

Single-acting radial sealing — pressure from one direction

Single-Acting
Pressure from one direction

Duty Shaft Diameter (mm | in) Pressure (MPa | psi) Temp. Range (°C | °F) Velocity (m/s)
Static radial sealing 3–2200 mm  (0.118–86.614 in) ≤20 MPa (approx. 2,901 psi) −200 to +320 °C (−328 to +608 °F) 0
*Important Note: Reference ranges depend on jacket grade, spring alloy and gland clearance. Confirm pressure at the operating temperature. Maximum values apply individually.

This configuration is specified for static service with pressure acting from one side. Dynamic operation and pressure reversal require a separate assessment.

Material Selection

Select the jacket and spring together to match the media, temperature, pressure and leakage requirements.

Jacket and spring options
Component Material selection
Sealing jacket Filled PTFE or another compatible engineering polymer, selected for the medium, service temperature and deformation resistance.
Canted coil spring energizer Stainless steel or another suitable spring alloy, selected for fluid compatibility, temperature and required spring load.

Hansealing manufactures canted coil spring energizers in-house, allowing spring dimensions and loading to be coordinated with the seal jacket and gland design. Check chemical compatibility.

Canted coil spring inside the HCC001 polymer seal jacket

Gland Dimensions & Installation

The drawings show stepped and split gland arrangements for housing-mounted static radial sealing. Select the gland dimensions for the shaft size and verify the extrusion gap at the intended operating pressure.

Dimensions are in millimetres, with inch equivalents in parentheses. Use the metric dimensions for machining. In formula cells, use the diameter in the units shown. L = E + 0.1 mm, or approximately E + 0.0039 in.

Symbols: d — shaft diameter; D — gland diameter; E — seal axial width; L — gland width; r — corner radius; X — retaining step height; Smax — maximum radial extrusion gap.

HCC001 gland dimensions — mm (in)
Shaft diameter
d (h9)
Gland diameter
D (H9)
Gland width
L = E + 0.1 mm
Corner radius
r
Retaining step
X
Maximum radial extrusion gap Smax
2 MPa 10 MPa 15 MPa 20 MPa
3.0–9.9(0.118–0.390) d + 2.6(d + 0.1024) 2.50(0.0984) 0.15(0.0059) 0.40(0.0157) 0.20(0.0079) 0.10(0.0039) 0.08(0.0031) 0.05(0.0020)
10.0–19.9(0.394–0.783) d + 3.6(d + 0.1417) 2.90(0.1142) 0.20(0.0079) 0.40(0.0157) 0.20(0.0079) 0.10(0.0039) 0.08(0.0031) 0.05(0.0020)
20.0–29.9(0.787–1.177) d + 4.6(d + 0.1811) 3.30(0.1299) 0.25(0.0098) 0.40(0.0157) 0.25(0.0098) 0.15(0.0059) 0.10(0.0039) 0.07(0.0028)
30.0–39.9(1.181–1.571) d + 5.6(d + 0.2205) 4.10(0.1614) 0.30(0.0118) 0.70(0.0276) 0.25(0.0098) 0.15(0.0059) 0.10(0.0039) 0.07(0.0028)
40.0–49.9(1.575–1.965) d + 6.6(d + 0.2598) 4.90(0.1929) 0.35(0.0138) 0.70(0.0276) 0.30(0.0118) 0.20(0.0079) 0.12(0.0047) 0.08(0.0031)
50.0–59.9(1.969–2.358) d + 7.6(d + 0.2992) 5.70(0.2244) 0.40(0.0157) 0.80(0.0315) 0.30(0.0118) 0.20(0.0079) 0.12(0.0047) 0.08(0.0031)
60.0–69.9(2.362–2.752) d + 8.6(d + 0.3386) 6.50(0.2559) 0.45(0.0177) 0.80(0.0315) 0.40(0.0157) 0.25(0.0098) 0.15(0.0059) 0.09(0.0035)
70.0–79.9(2.756–3.146) d + 9.6(d + 0.3780) 7.30(0.2874) 0.50(0.0197) 0.90(0.0354) 0.40(0.0157) 0.25(0.0098) 0.15(0.0059) 0.09(0.0035)
80.0–89.9(3.150–3.539) d + 10.6(d + 0.4173) 8.60(0.3386) 0.55(0.0217) 0.90(0.0354) 0.50(0.0197) 0.30(0.0118) 0.20(0.0079) 0.10(0.0039)
90.0–109.9(3.543–4.327) d + 11.6(d + 0.4567) 9.10(0.3583) 0.60(0.0236) 0.90(0.0354) 0.50(0.0197) 0.30(0.0118) 0.20(0.0079) 0.10(0.0039)
110.0–129.9(4.331–5.114) d + 12.6(d + 0.4961) 9.70(0.3819) 0.65(0.0256) 1.00(0.0394) 0.60(0.0236) 0.35(0.0138) 0.25(0.0098) 0.12(0.0047)
130.0–149.9(5.118–5.902) d + 13.6(d + 0.5354) 10.50(0.4134) 0.70(0.0276) 1.00(0.0394) 0.60(0.0236) 0.35(0.0138) 0.25(0.0098) 0.12(0.0047)
150.0–169.9(5.906–6.689) d + 14.6(d + 0.5748) 11.30(0.4449) 0.75(0.0295) 1.00(0.0394) 0.70(0.0276) 0.40(0.0157) 0.30(0.0118) 0.14(0.0055)
170.0–189.9(6.693–7.476) d + 15.6(d + 0.6142) 12.10(0.4764) 0.80(0.0315) 1.00(0.0394) 0.70(0.0276) 0.40(0.0157) 0.30(0.0118) 0.14(0.0055)
190.0–209.9(7.480–8.264) d + 16.6(d + 0.6535) 12.90(0.5079) 0.85(0.0335) 1.00(0.0394) 0.80(0.0315) 0.45(0.0177) 0.35(0.0138) 0.15(0.0059)
210.0–249.9(8.268–9.839) d + 17.6(d + 0.6929) 13.70(0.5394) 0.90(0.0354) 1.00(0.0394) 0.80(0.0315) 0.45(0.0177) 0.35(0.0138) 0.15(0.0059)
250.0–299.9(9.843–11.807) d + 18.6(d + 0.7323) 14.50(0.5709) 0.95(0.0374) 1.00(0.0394) 0.90(0.0354) 0.50(0.0197) 0.40(0.0157) 0.18(0.0071)
300.0–2200.0(11.811–86.614) d + 19.6(d + 0.7717) 15.30(0.6024) 1.00(0.0394) 1.00(0.0394) 0.90(0.0354) 0.50(0.0197) 0.40(0.0157) 0.18(0.0071)

Confirm the allowable gap for the selected jacket, temperature and assembled tolerances. Request a size-specific drawing for large diameters.

Installation Notes

  • Install the open side of the seal toward the pressure source.
  • Remove burrs and protect the sealing lip from sharp edges, threads and ports during assembly.
  • Check the extrusion gap using the assembled dimensions and tolerances.
  • Use the confirmed gland drawing and avoid stretching or twisting the seal during installation.

Hardware Surface Finish

Specify the finish of the stationary shaft and housing contact surfaces together with the allowable leakage. Include surface coatings and any dimensional changes at operating temperature.

Surface finish reference
Medium Static sealing surface, Ra
Cryogenics, Helium gas, Hydrogen gas, refrigerants 0.2 µm (8 µin) Ra max
Air, Nitrogen gas, Argon gas, Natural gas, Fuel (aircraft, automotive) 0.4 µm (16 µin) Ra max
Water, Hydraulic oil, Crude oil, Sealants 0.8 µm (32 µin) Ra max

These general surface-finish references are not a media-compatibility approval or leakage guarantee for HCC001. Confirm the final drawing requirements for the selected application.

Sealing Surface Inspection

Check the seal contact bands for scratches, porosity and machining marks that could form leakage paths. Surface finish and maximum radial extrusion gap are separate drawing requirements.

Request a Quote for HCC001

Send a drawing or describe the operating conditions for your HCC001 seal.

I Have a Drawing or Existing Seal

Send the assembly drawing, part number or sample dimensions, together with the drawing revision, operating conditions and required quantity.

Send Your Drawing →

I Need a New Sealing Solution

Send the shaft diameter, available gland space, steady and peak pressure, temperature range, media and required leak rate.

Discuss Your Application →

Related: Canted Coil Spring Seals · Gland design and installation