A spring-load figure is useful only when its deflection, units and test conditions are known. For an annular energizer, distinguish load per unit circumference from the total force measured on an assembly.
Start with free spring height and installed spring height, measured in the loading direction. Their difference is the installed deflection. Use spring cavity dimensions for this calculation. Overall jacket height can include the heel and lip features and may give a different result.
| Condition | Question to answer |
|---|---|
| Least compression | After tolerance variation, thermal movement and wear, does the spring still provide enough contact load? |
| Nominal compression | Does the target load meet the leakage and friction requirements at the specified temperature? |
| Greatest compression | Does the design remain within its usable spring travel and assembled force limit? |
A line load may be stated in N/mm of circumference or lbf/in of circumference. Provide the reference diameter and deflection for that value. A force measured on a spring segment and the force needed to move a finished rod seal describe different tests.
In a radial seal, jacket interference, pressure loading, lubrication and surface finish also affect sliding friction. Do not convert radial spring line load directly into axial actuator force.
For a spring test, specify the fixture orientation, reference length or diameter, loading direction and whether the limit applies on loading or unloading. For a finished dynamic seal, report breakaway force after a defined dwell and running force at a defined speed, pressure and temperature.