This browser is no longer supported. Upgrade to Microsoft Edge or switch to a supported browser, like Chrome, Safari, or Firefox, to explore the Hansealing website.

We're sorry for the inconvenience.

Home  >  Technical Resources  > Pressure, Extrusion Gap and Heel Design

Pressure, Extrusion Gap and Heel Design

Differential pressure can force jacket material into an unsupported hardware gap. The critical section is the clearance on the low-pressure side under operating conditions. Its size may differ from the nominal clearance shown on the drawing.

Determine the largest unsupported gap

Mark the high- and low-pressure sides on a section through the seal. Include tolerances, rod or piston displacement, thermal expansion and deflection under pressure. For a face seal, include axial separation of the joint.

Example: a 20.20 mm bore around a 20.00 mm rod has 0.20 mm diametral clearance. When concentric, the one-sided radial clearance is 0.10 mm. If the rod shifts by 0.05 mm, the larger local clearance becomes 0.15 mm before any other allowances. These figures illustrate the calculation only.

Match support to the hardware

Option What it changes What to verify
Standard heel Supports the jacket behind the spring cavity. Compare the largest local gap with the approved series limit at service pressure and temperature.
Extended heel Adds jacket material and support length in the direction provided by the profile. Verify groove space, pressure direction and the actual support behind the heel.
Backup ring Adds a separate support element at the extrusion gap. Check the backup ring material, fit, pressure side and support during pressure reversal.

Read the clearance table for the selected series

Identify the dimension marked Smax or maximum extrusion gap on the corresponding gland drawing. Read the pressure band, size band and units together. If the pressure falls outside the table, obtain a reviewed limit. Higher temperature and long dwell under load can make polymer creep more significant.

For a static internal-pressure face joint, HS006 is an extended-heel example. Its allowable gap must be taken from the applicable drawing and material specification.